Archive for category Thermocouple Attachment
UV Cure Epoxy
Posted by Paul Austen in Thermocouple Attachment, UV Cure Epoxy on April 29th, 2009
Thermocouple Attachment - UV Cure Epoxy®

Test Thermocouples attached with UV cured Epoxy
UV Cure Epoxy® provides solid contact with very short cure times
What are some advantages of UV Cure Epoxy?
Stable – good long term
Cures in 10 seconds
Can be attached to metals and plastics
Does not require heating to cure
What are some of the disadvantages of UV Cure Epoxy.
Requires about $1500 to $2000 UV light source
Difficult to remove without damaging product
Difficult to recover thermocouple
Cyanoacrylates (Super Glue)
Posted by Paul Austen in Cyanoacrylates (Super Glue), Thermocouple Attachment on April 29th, 2009
Thermocouple Attachment – Cyanoacrylate (Super Glue)

Cyanoacrylates (Super Glue) used to attach T/Cs for testing
Cyanoacrylate glue is sometimes used but is not the best
What are some advantages of cyanoacrylates?
It is easy to apply
Hardens quickly
Easy to remove
Available on most manufacturing floors
Makes an OK wire strain relief
What are some of the problems with cyanoacrylates?
Not made to take solder temperatures
Tends to “evaporate” at solder temp and will burn away with repeated runs resulting in increasing temperature readings with each use
Is a good insulator, so if too thick, will suppress the temperature value.
Thermocouple response time
Posted by Paul Austen in Response Time, Thermocouple Attachment, Thermocouples on March 20th, 2009
The response time of a thermocouple is affected by several factors
The main factors affecting thermocouple response time are thermocouple bead size and the conducting medium including attachment method.
Thermocouples response time is measured as a “time constant.” The time constant is defined as the time required for a thermocouple’s voltage to reach 63.2% of its final value in response to a sudden change in temperature. It takes five time constants for the voltage to approach 100% of the new temperature value.
Thermocouples attached to a heavy mass will respond much slower than one that is left free standing because its value is governed by the temperature of the large mass. A free standing (exposed or bare wire) thermocouple’s response time is a function of the wire size (or mass of the thermocouple bead) and the conducting medium. A thermocouple of a given size will react much faster if the conducting medium is water compared to still air.
Here are some typical time constants of various free standing thermocouple bead sizes (bead size is typically 2 times the diameter of the wire) in these conducting mediums:
Wire (AWG) Bead Size (inches) Still Air (sec) Water (sec)
42 0.003 0.07 0.003
40 0.005 0.25 0.02
36 0.010 1 0.05
30 0.020 4 0.17
NOTE: Remember it takes five time constants for a thermocouple to reach 100% of the final temperature value so the above time constants must be multiplied by 5 to get the total time.

So the most common sizes (30 AWG or smaller) of thermocouples used to attach to surfaces or components will have fast enough response time to accuracelly measure the temperatures of reflow solder process which tend to change no faster then 5 degrees/second. If one wishes to measure the air temperature, 36 AWG is common since the air is always moving, and the chart reflects “still air” response times.
The main reason for selecting thermocouples of a specific size is to match the size of the surface or point where the thermocouple is to sense temperature. 36 AWG is a good compromise between cost, size, and strength. Much smaller and it is too easy to break. Much bigger and it may be bigger then the component or attachment point.
One other factor in selecting thermocouples is the heat source. In wave soldering, the heat is typically from the bottom of the assembly and the thermocouples are attached on top. Here the thermocouples will be cooler then bottom of the assembly causing them the sink the heat as it flows from the bottom to the top. Smaller thremocouples will reduce the heat sinking effect.
In reflow soldering, both the top and the bottom of the assembly are heated at about the same rate causing the thermocouple wire and its bead to heat as fast as the assembly. Some times the thermocouple can heat faster then the assembly because it is closer to the heat source and can act as a heat source to the component. This is often true where there is exposed thermocouple wire where the insulation has pulled back from the bead more then 0.5 inches. Keeping the insulation closer to the bead prevents this in most cases.
Box and Whisker Plots
Posted by Rex Breunsbach in Thermocouple Attachment, Thermocouples on March 9th, 2009
Box whisker plots are particularly useful for illustrating change variations between different data sets.
Box-whisker plots are a great way to show how stable the different thermocouple attachment methods are relative to each other.
The top dot is the Maximum value and the bottom dot is the Minimum value from the data set. The top of the box is the 75th Percentile (AKA: 3rd Quartile) and the bottom of the box is the 25th Percentile (AKA: 1st Quartile). This makes the Median, the red dot, the 50th Percentile (AKA: 2nd Quartile). Percentile is a number describing the data set such that the K-th Percentile is a number such that K % of all data values are less and (100 – K) % are larger than it, or to be more precise, at least K% of the sorted values are less than or equal to it and at least (100 – K) % of the values are greater than or equal to it.
Aluminum Foil – Framed in Kapton Tape
Posted by Rex Breunsbach in Aluminum Foil Framed in Kapton, Thermocouple Attachment on March 5th, 2009
Thermocouple Attachment – Aluminum Foil with Kapton Tape
Aluminum foil promotes solid contact with surfaces – Kapton tape adds adhesion insurance
What are some advantages of Aluminum Foil Framed in Kapton Tape?
Easy to remove without damage to product
Stable – good long term
Allows use of smaller pieces of foil while maintaining adhesion
What are some of the disadvantages of Aluminum Foil Framed in Kapton Tape.
Two step operation requires more time
Sticky T/C – M.O.L.E.® AttachEz™
Posted by Rex Breunsbach in AttachEZ, Thermocouple Attachment on March 5th, 2009
Thermocouple Attachment – Sticky T/C – M.O.L.E.® AttachEz™

The Sticky T/C is easy to attach and remove multiple times
What are some advantages of Sticky T/C?
Quick and easy to attach and remove
Does not damage product
Can be attached to metals and plastics
Provides identification of instrument input channel number
Able to see through and accurately place thermocouple
What are some of the disadvantages of Sticky T/C.
Not usable with small or irregular surfaces such as component leads
Temprobe®
Posted by Rex Breunsbach in Temprobe(r), Thermocouple Attachment on March 5th, 2009
Thermocouple Attachment – Temprobe®

The Temprobe is the easiest to use and remove attachment method
What are some advantages of Temprobe?
Quick and easy to attach and remove
Works well on “wet” solder paste
Does not damage product
Can be attached to metals and plastics
Sheathed construction protects thermocouple
What are some of the disadvantages of Temprobe.
Requires 1/2- 3/4 inch virtical clearence above board in oven
Epoxy – Air Cured
Posted by Rex Breunsbach in Epoxy, Thermocouple Attachment on March 5th, 2009
Thermocouple Attachment - Epoxy

Air Dry Epoxy provides solid contact but requires time to cure
What are some advantages of Epoxy?
Stable – good long term
Can be attached to metals and plastics
Easy to see
What are some of the disadvantages of Epoxy.
Proper cure may require hours
Difficult to remove without damaging product
Difficult to recover thermocouple
Aluminum Foil – Adhesive Backed
Posted by Rex Breunsbach in Aluminum Foil, Thermocouple Attachment on March 5th, 2009
Thermocouple Attachment – Aluminum Foil
Aluminum foil promotes solid contact with surfaces
What are some advantages of Aluminum Foil?
Easy to apply
Easy to remove without damage to product
Stable – good long term
Accurate – Can be attached to very small components
What are some of the disadvantages of Aluminum Foil.
Does not work well with very small contact areas such as component leads
Cannot see through it to know where thermocouple is placed
High Temperature Solder
Posted by Rex Breunsbach in Solder, Thermocouple Attachment on March 5th, 2009
Thermocouple Attachment – High Temperature Solder
High temperature solder is probably the most stable method of attachment
What are some advantages of Hi Temperature Solder?
Stable – long term with proper metal surfaces
Accurate – Can be attached to very small components
What are some of the disadvantages of Hi Temperature Solder.
Does not stick to many materials
May affect solder joint alloy composition
Expensive
Soldering skill required
You can buy high-temp solder here
-
-
You are currently browsing the archives for the Thermocouple Attachment category.
Aluminum Foil AttachEz Bead Calibration Cyanoacrylate Epoxy G R&R Hi-Rel Insulation IPC J-STD-075 Machine Process Control MEGAMOLE MEGARIDER Multiple Conveyor Speeds Ok Button OvenCHECKER Oven HealthCHECK Oven Profile OvenRIDER Oven Verification Profile reflow profile Reflow Soldering RoHS Silicon Diffusion Silicon Metallization SMT Oven Solar Solder SPC Stickey T/C Super M.O.L.E. Gold Tape Temprobe Thermal Profile Thermal Profiler Thermocouple Thermocouple Attachment V-MOLE WaveRIDER Wave Solder